Standard Technical Features of BTG System for Supercritical 660/800 MW Thermal Units
114
ii) Best efficiency
point
Combined flow of 2x50%
TDBFPs shall be based on
TMCR requirement
and corresponding head.
iii) Emergency point Two turbine driven feed
pumps to be capable of
generating the discharge
pressure corresponding to
steam generator highest
safety valve set pressure at
100% BMCR flow.
Requirement of
emergency point
shall be met by
MDBFP at 50
Hz grid frequency.
iv) Other Capabilities Combined flow of 2x50% TDBFP shall meet the
following:
a) BMCR flow and head corresponding to rated
steam pressure.
b) V.W.O. output, 1% makeup, worst condenser
pressure (MDBFP should meet the
corresponding requirement at 47.5Hz).
v) Rated discharge
flow through
interstage bleed off
for reheater
attemperation
As per 8% of maximum reheat steam flow for
the unit as a minimum.
Note: Discharge flow of main pump not to include any seal flow, warm-up
flow and balance drum leakage flow.
15.3 Design Requirements
15.3.1 Pumps
i) NPSH Margin: The ratio between NPSH (A) and NPSH (R) at 3%
head drop for booster pump and main pump shall be not less than 2.5 at
design point corresponding to lowest level of deaerator and maximum
pressure drop across the suction strainer.
ii) Trip Speed of TD-BFP: 10% above the design speed of the feed pump.
iii) Performance Curve: The characteristic curves of booster pump and
main pump should be continuously rising type with decrease in flow
and shut off head shall be in the range of 115% to 130% of TDH at
design point.
iv) Minimum Recirculation: The minimum flow of the booster pump and
main pump shall not be less than 25% of design flow. ON-OFF or
modulating type minimum recirculation valve with valve body
designed for about 40% of design flow shall be provided.