24
tic water needs. Because hot water presents a scald hazard, it is best to set the thermostat at 120ºF or lower and raise it
only if necessary to provide adequate hot water. See Table 9.2 for more information about scalding.
setting on the dial is aligned with the notch in the temperature indication window.
b) After the water heater completes a heat-up cycle, check the water temperature at the faucet. Allow enough
temperature setting as necessary.
i) Adjusting to a lower temperature setting will not immediately affect the water temperature. Draw
ii) Adjusting to a higher temperature setting may not immediately affect the water temperature if
water or allow the water heater to sit until a heat-up cycle is initiated. Repeat steps a) and b).
X. MAINTENANCE
The Mega-Stor is an extremely simple device and as such requires very little maintenance. There are, however, several items
which should be checked out on an annual or as needed basis to ensure a reliable supply of hot water:
* On an annual basis, remove the black cover over the handhole and make sure that the handhole cover is leak-tight.
* Make sure that the rest of the boiler and domestic water piping is free of leaks.
* If there is an oil lubricated circulator in the system, make sure that it is lubricated as called for by the circulator
manufacturer.
* The Mega-Stor depends upon the boiler for a source of heat and is therefore only as reliable as the boiler. Make sure
that the boiler is maintained in accordance with the boiler manufacturer’s instructions.
* If a water treatment system is required to keep the water chemistry within the parameters shown in Table 5.1, make
sure that this system is properly maintained.
40
60
FIGURE 9.1: TEMPERATURE CONTROL
APPROXIMATE TIME/TEMPERATURE
RELATIONSHIPS FOR SCALDING
More than 5 minutes
1-1/2 to 2 minutes
About 30 seconds
About 10 seconds
Less than 5 seconds
Less than 3 seconds
About 1-1/2 seconds
About 1 second
TABLE 9.2: SCALD RISK
Comments to this Manuals